LIGHTING DESIGN · DIALUX · INSTALLATION

Lighting design: lux and scene plans, DIALux calculation and installation in one hand

Good lighting does not start with choosing luminaires but with what happens in the room: where people read, cook or work, and where mood lighting is enough. This becomes the lux plan (how much light, and where) and the scene plan (which luminaires switch together, at what level). We also provide calculated (DIALux) lighting designs with our partner, and we do the installation — so design and installation stay in one hand.

What does lighting design include?

The result of lighting design is not a list of luminaires but a plan from which wiring and control can be built directly. Room by room we define:

Needs and functionsWhat happens in the room, where work surfaces, furniture and pictures are, how much daylight there is.
Lux planThe illuminance needed per room and work surface; in workplaces to EN 12464-1.
Luminaires and light sourcesBeam angle, colour temperature, colour rendering (CRI), glare (UGR), dimmability, driver type.
Scene planWhich luminaires form a circuit, which are dimmable, which scenes are needed (cooking, dinner, cinema, cleaning).
ControlWall dimmer, DALI, KNX or wireless Casambi — chosen for the state of the house and the number of scenes.
Electrical integrationCircuits, driver positions, cabling and board space, so the electrical design and the installation start from the same plan.

Lux plan or scene plan: what is the difference?

PartQuestion it answersResult
Lux planhow much light the desk, worktop or corridor needs; whether it is evennumber, position and power of luminaires
Scene planwhich luminaires switch together, at what level and colour temperaturecircuits, groups, scenes, control programming
Calculated (DIALux) designwhether illuminance, uniformity and glare requirements are metcalculation report and visualisation from real photometric data

In a family house the lux and scene plans matter most; a calculated design is needed when the lighting has to be verified, or when room geometry and luminaires make experience alone insufficient.

When is a calculated DIALux lighting design needed?

DIALux is the lighting design software of DIAL GmbH: from the manufacturers’ photometric data it calculates illuminance, uniformity and glare and produces a visualisation. We also provide calculated (DIALux) lighting designs with our partner; we carry the result into the construction drawings and the installation.

  • Workplaces: offices, shops, practices, workshops, halls — where compliance with EN 12464-1 for indoor workplaces has to be shown.
  • High ceilings or special geometry: galleried living rooms, lofts, halls, where light distribution cannot be judged by eye.
  • Choosing luminaires: when comparing several manufacturers, the calculation shows which meets the requirement with fewer luminaires.
  • Retrofits: when replacing old luminaires with LED, the calculation proves that fewer or lower-power luminaires are enough — see hall lighting and industrial LED retrofit.

How much light is needed? Reference values from EN 12464‑1

There is no mandatory lux value for homes; for workplaces EN 12464-1 sets the maintained average illuminance (Ēm), uniformity (U₀), colour rendering (Ra) and glare limit (UGR) per activity. Some reference values:

ActivityĒm (lx)Note
Writing, typing, reading, data processing (office)500UGR ≤ 19, Ra ≥ 80, U₀ ≥ 0.60
Filing, copying300UGR ≤ 19, Ra ≥ 80
Storage, circulationfrom 100the exact value depends on the activity
Rough work200–300the row for the activity decides
Fine workfrom 1000together with local task lighting

Ēm is a maintained value: it must still be met after the luminaires have aged and got dirty, so the initial design illuminance is higher, divided by the maintenance factor (e.g. 300 lx ÷ 0.8 = 375 lx). The exact requirement is always the table row for the activity.

Why have the same team design and install the lighting?

The design can be builtLuminaire positions follow the slab, the drywall, the furniture and driver access, not just the rendering.
Control matches the luminaireDriver (DT6 or DT8), dimmer and controller are chosen together; flicker or non-dimmable lamps are not discovered on site.
Exact priceThe design becomes an itemised quote by luminaire, driver, cable and programming.
One responsible partyIf the light is not as designed, there are not two companies to argue about why.

How does the lighting design process work?

  1. Briefing floor plan, wall elevations, furnishing plan; how the rooms are used and the mood you want.
  2. Lux and scene plan luminaire positions, circuits, scenes, control method; a calculated DIALux design with our partner if needed.
  3. Luminaire and driver list manufacturer, type and driver; for DALI from Lunatone, TCI, Helvar or Casambi devices.
  4. Electrical integration cabling, boxes and board space in the electrical design, before plastering or drywall.
  5. Installation and programming installation, commissioning, setting the scenes and fine-tuning after you move in.

More on related pages: LED lighting and lighting control · DALI lighting control · Human centric lighting, tunable white · Electrical design

Frequently asked questions

How much does lighting design cost?

It depends on the number of rooms, the design level (lux and scene plan or calculated DIALux design) and the control method. We quote in writing, item by item, from the floor plan; if we also install, the design is the basis of the installation quote.

Do you provide DIALux lighting calculations?

Yes, we provide calculated (DIALux) lighting designs with our partner. The calculation uses the manufacturers’ photometric data and shows illuminance, uniformity and glare; in workplaces it shows compliance with EN 12464-1.

Does a family house need lighting design?

There is no mandatory lux value for homes, but lux and scene plans still pay off: before plastering you decide where luminaires go, which circuits dim and where drivers sit. These are the most expensive things to change later.

Do you offer design only, without installation?

Yes, design can be ordered on its own. It brings most benefit, however, if we also install, because luminaire, driver and control are selected and set up together.

Let’s talk about your project.

Tell us what you are planning and we will get back to you within a few days.

Get in touch

Cookie settings

Choose what you consent to. We remember your choice for 6 months; change it any time via “Cookie settings” in the footer.

Privacy notice