KNOWLEDGE BASE · LIGHTING

Bathroom lighting: zones, IP ratings and mirror lighting

In a bathroom the position of a light is set by the zones (HD 60364-7-701): inside the bath and on a walk-in shower floor is zone 0 (IPX7, extra-low voltage only), above it up to 225 cm is zone 1 (IPX4), and a 60 cm strip next to the bath is zone 2 (IPX4). Every bathroom circuit is protected by a 30 mA RCD, and switches and sockets go outside the zones. Good bathroom lighting has two layers on top of that: even ceiling light and mirror lighting from the side at face height.

In short

  • Zone 0 (inside the bath, walk-in shower floor up to 10 cm): IPX7, extra-low voltage only, max. 12 V AC or 30 V DC, supply outside zones 0 and 1.
  • Zone 1 (above the bath, up to 120 cm from the shower outlet, up to 225 cm high): IPX4, fixed equipment suitable for zone 1, or extra-low voltage.
  • Zone 2 (60 cm next to the bath): IPX4; no mains socket, only a shaver supply unit.
  • Every circuit with an RCD of max. 30 mA; switches and sockets outside the zones.
  • Light: ceiling light plus mirror lighting at face height, Ra ≥ 90, 3000–4000 K.

Author: Norbert Madarász, Managing Director and Partner · Updated: 14 November 2026

Bathroom zones: what is allowed where?

The zones describe the distance from water. Dimensions according to IEC 60364-7-701:2019 (on which HD 60364-7-701 is based):

Bathroom zones (side view)225 cmzone 0 · IPX7bathzone 1IPX4zone 2IPX460 cmzone 1IPX4walk-in showerzone 0 (10 cm)120 cm from the outletoutside the zones: switches, socketsevery circuit with 30 mA RCD protection
Zones according to IEC 60364-7-701:2019 (HD 60364-7-701). A walk-in shower has no zone 2; zone 1 extends 120 cm from the outlet. A fixed partition can reduce this.
ZoneExtentRatingWhat is allowed
0inside the bath or shower tray; for a walk-in shower up to 10 cm above the floor, within 120 cm of the outletIPX7SELV only, max. 12 V AC / 30 V DC, supply outside zones 0 and 1
1above the bath, or up to 120 cm from the shower outlet, up to 225 cm high (or the fixed shower head, if higher)IPX4SELV/PELV max. 25 V AC / 60 V DC, or fixed equipment suitable for zone 1
2for a bath a 60 cm strip beyond zone 1, up to 225 cm; none for a walk-in showerIPX4lights and accessories with IPX4; sockets only SELV/PELV or shaver supply units

Where water jets are used for cleaning (e.g. communal showers), IPX5 is required. A fixed partition or glass screen can reduce a zone; we measure this on site together with the plan.

RCD, switches and sockets in the bathroom

  • RCD: every circuit serving the bathroom, and circuits passing through zones 1 and 2, are protected by an RCD of max. 30 mA (except SELV, PELV and electrical separation). Types: RCD types.
  • Switch: outside the zones, usually next to the door; if it has to be in zone 2, at least IPX4.
  • Socket: outside the zones; in zone 2 only extra-low-voltage sockets or shaver supply units.
  • Extractor fan and mirror cabinet: their own connection point before tiling; the cabinet’s light and socket are connected per the manufacturer’s datasheet.

If old wiring stays during a bathroom renovation, check its condition first: older houses often have no earth wire and no RCD. See: connecting a light fitting.

Ceiling spots, LED strips, shower lighting

  • Recessed spots: at least IPX4 from the front above zone 1; we recommend this throughout the bathroom. The driver goes somewhere accessible, not above the shower.
  • Light strip in the shower or niche: that is zone 1 or 0, so a 24 V waterproof (IP67/IP68) LED strip with the driver outside the zones.
  • Plasterboard ceiling: spots, drivers and mirror-light cables before the boards go up; details: hidden LED strip lighting in drywall.
  • Night light: low, warm white plinth light on a motion sensor – no glare at night.

Mirror lighting: where should the light come from?

A single light above the mirror lights the face from above and casts shadows under the eyes and chin. For shaving and make-up, light at face height from the sides or around the mirror is better, and even.

AspectOur adviceWhy
Positionon both sides at face height, or a light strip around the mirrorshadow-free face
Colour renderingRa ≥ 90, R9 on the datasheettrue skin tones and make-up; the EU minimum is Ra ≥ 80
Colour temperature3000–4000 K, dimmed in the eveninglively in the morning, calm in the evening
Glareopal diffuser, no visible LED dotsin a mirror you see the source twice

What Ra and R9 mean: CRI, R9 and TM-30.

IKEA, EGLO, Rábalux bathroom lights: what to check on the box

The “bathroom light” category in an online shop does not tell you which zone the light is suitable for. Whatever the brand (IKEA, EGLO, Rábalux, Kanlux), what counts is what the box and the rating label say:

MarkingWhat it means in the bathroom
IP code (e.g. IP44)the second digit is the protection against water: zones 1 and 2 need at least IPX4, zone 0 IPX7
No IP marking (IP20)outside the zones only, e.g. on the ceiling away from the bath
Protection classa class I light needs a protective earth at the outlet
Mirror light or cabinet with a socketthe socket must be outside the zones; in zone 2 only a shaver supply unit

If the light you bought does not suit the planned position, we tell you during the survey and either move the light or suggest another type. We also install lights bought elsewhere; see how to connect a light fitting.

What to decide before tiling

  1. Bath, shower and basin positions: they define the zones, so we fit lights and boxes to the tiling plan.
  2. Ceiling lighting: number and position of spots; on request a calculated lighting design (DIALux) through our partner.
  3. Mirror: size, built-in or separate mirror light, mirror cabinet with socket.
  4. Control: switch, dimmer, motion sensor for the night light; KNX in a smart home.
  5. Distribution board: bathroom circuits with a 30 mA RCD, a separate circuit for the fan and towel heater if needed.
We do the bathroom’s electrical work from design to connection. No price list: we quote after a site visit or from the tiling plan.

Related: LED lighting and lighting control · Electrical installation

Frequently asked questions

Which IP rating does a bathroom light need?

IPX7 in zone 0, at least IPX4 in zones 1 and 2; IPX5 where water jets are used for cleaning. We recommend IP44 outside the zones too.

How large are the bathroom zones?

Zone 0 is inside the bath or tray (10 cm above the floor for a walk-in shower). Zone 1 is above it up to 225 cm, for a shower up to 120 cm from the outlet. Zone 2 is a 60 cm strip next to zone 1 for a bath; a walk-in shower has none.

Does a bathroom need an RCD?

Yes: every circuit serving the bathroom is protected by an RCD of max. 30 mA, except SELV and PELV circuits.

Where can a socket go in a bathroom?

Outside the zones. In zone 2 only an extra-low-voltage socket or a shaver supply unit is allowed.

Can I have an LED strip in the shower?

Yes, a 24 V waterproof (IP67/IP68) strip with the driver outside the zones; in zone 0 max. 12 V AC or 30 V DC.

What light is best at the bathroom mirror?

Opal light at face height from the sides or all around, Ra ≥ 90, 3000–4000 K. Light only from above casts shadows on the face.

Can an IKEA or EGLO bathroom light go above the shower?

Only if the rating label says at least IPX4 and the manufacturer states it is suitable for zone 1; inside the shower tray (zone 0) an IPX7 extra-low-voltage light is needed. A light without IP marking can only go outside the zones.

Let’s talk about your project.

Tell us what you are planning and we will get back to you within a few days.

Get in touch

Cookie settings

Choose what you consent to. We remember your choice for 6 months; change it any time via “Cookie settings” in the footer.

Privacy notice