KNOWLEDGE BASE · LIGHTING

CRI, R9 and TM-30: how much colour rendering do homes and offices need?

The CRI (colour rendering index, symbol Ra) measures how faithfully a light source shows colours compared with a reference light, on a scale up to 100. Ra is the mean of eight moderately saturated test colours; saturated red (R9) is not included, so under an Ra 80 LED skin, meat, wood and red fabric can look dull. The EU requires Ra ≥ 80 for indoor light sources, and EN 12464-1 sets Ra ≥ 80 for office workplaces. For homes we recommend Ra ≥ 90 with a high R9 stated on the datasheet; TM-30 (Rf, Rg) gives a more precise picture.

In short

  • Ra (CRI): mean of test colours R1–R8 (CIE 13.3-1995), max. 100.
  • R9: separate index for saturated red; on LEDs it can be low despite a good Ra. In the EU it must be declared on the product sheet (EPREL); there is no minimum.
  • TM-30: uses 99 colour samples; Rf gives fidelity, Rg gamut (saturation).
  • Requirements: EU minimum indoors Ra ≥ 80; offices (EN 12464-1:2021) Ra ≥ 80; colour inspection, examination rooms Ra ≥ 90.
  • Our advice for homes: Ra ≥ 90, R9 at least 50, and every light in a room with the same white.

Author: Norbert Madarász, Managing Director and Partner · Updated: 10 November 2026

What does CRI (Ra) measure, and what is R9?

Under CIE 13.3-1995, 14 test colours are compared under the light source and under a reference light of the same colour temperature. Each sample gives a special index (R1–R14); Ra is the mean of the first eight, moderately saturated samples. The other six are saturated red (R9), yellow (R10), green (R11), blue (R12), skin tone (R13) and foliage (R14).

Ra (CRI) and R9: what the number measuresR1R2R3R4R5R6R7R8R9R10R11R12R13R14Ra = mean of R1–R8R9: saturated red – not part of RaHow much Ra do you need?EU minimum (2019/2020)Ra ≥ 80office, EN 12464-1Ra ≥ 80colour inspection, examinationRa ≥ 90our advice for homesRa ≥ 90+ and R9 on the datasheetcolour patches are illustrative
Under CIE 13.3-1995, Ra is the mean of eight moderately saturated test colours; saturated red (R9) is a separate index. That is why an Ra 80 LED can render reds poorly.

The spectrum of white LEDs is often weak in deep red. The Ra average hides this; R9 shows it: the same Ra 80 lamp looks fine on a white wall but dull on a red sofa, a bowl of tomatoes or skin. That is why we check R9 separately.

The ecodesign regulation (EU) 2019/2020 requires the R9 value to be published on the product information sheet (EPREL) of LED light sources, but sets no minimum. The packaging shows Ra (rounded) or the range of Ra values that can be set.

What do standards and the EU require?

SourceRequirementNote
(EU) 2019/2020, Annex IIindoor light sources: Ra ≥ 80 (from 1 September 2021)exceptions for outdoor, industrial and HID above 4000 lm, if the packaging says so
EN 12464-1:2021, office (writing, reading, typing)500 lx (modified up to 1000 lx), UGR ≤ 19, Ra ≥ 80for workplaces, not mandatory at home
EN 12464-1:2021, colour inspection, examination roomsRa ≥ 90printing, textiles, paint, medical examination
EPREL product sheet (2019/2015)R9 value must be declaredno R9 minimum

The same regulation also covers flicker: Pst LM ≤ 1.0 for mains LED light sources, and for the stroboscopic effect SVM ≤ 0.4 from 1 September 2024 (0.9 before that, as amended by (EU) 2021/341).

TM-30: Rf and Rg, and why it does not (yet) replace Ra

IES TM-30 uses 99 colour samples and gives two numbers: Rf (0–100) for fidelity and Rg for gamut (100 = neutral, above is more saturated, below duller). The colour vector graphic also shows which hues shift. CIE 224:2017 adopted the same Rf, but according to CIE it is not meant to replace Ra in product rating and regulations; regulations and EN 12464-1 still use Ra.

TM-30 recommended levels (Annex E, at typical interior 200–700 lx):

Design intentLevelCriteria
PreferenceP1 / P2 / P3Rf ≥ 78 / 74 / 70, Rg ≥ 95 / 92 / 89, and red chroma shift (Rcs,h1) within the given band
FidelityF1 / F2 / F3Rf ≥ 95 / 90 / 85; for F2 and F3 red fidelity (Rf,h1) also at least 90 / 85
VividnessV1 / V2 / V3Rg ≥ 118 / 110 / 100, Rcs,h1 ≥ 15 / 6 / 0 %

How much colour rendering do homes and offices need?

SpaceOur adviceWhy
Living, dining, bedroomRa ≥ 90, R9 ≥ 50natural skin, wood and fabric, also with warm white in the evening
KitchenRa ≥ 90, R9 ≥ 50true food colours (meat, vegetables)
Bathroom, mirrorRa ≥ 90make-up, shaving
Office, home officeRa ≥ 80 (EN 12464-1), Ra ≥ 90 for colour work80 is fine for screen work, not for graphics or print
Pantry, garage, utility roomRa ≥ 80the EU minimum is enough

R9 ≥ 50 is our own design recommendation, not a standard value. Besides colour rendering, colour consistency matters: all lights in a room should have the same colour temperature and a tight binning (MacAdam steps on the datasheet), otherwise neighbouring spots give different whites. Kitchen and living room: kitchen and living room lighting; LED strips: hidden LED strip lighting.

How to read the datasheet

  1. Ra (CRI): “CRI > 80” or “Ra 90” is the minimum; if it only says “high CRI”, ask for the number.
  2. R9: serious manufacturers state it; if not on the datasheet, the EPREL database lists it for the light source.
  3. TM-30 (Rf, Rg): more and more manufacturers publish it; Rf ≥ 90 with Rg around 100 means good, balanced light.
  4. Colour temperature and binning: e.g. 3000 K, 3-step MacAdam or less – so the white matches.
  5. Measured at which setting: for tunable white, colour rendering can depend on colour temperature; check it across the range (human centric lighting).
We help choose luminaires and light sources from datasheets and do the installation and controls ourselves. No price list: we quote after a site visit or from a design.

Related: LED lighting and lighting control · DALI lighting control

Frequently asked questions

What is CRI, the colour rendering index?

It measures how faithfully a light source shows colours compared with a reference light. Ra is the mean of eight test colours under CIE 13.3-1995, max. 100.

What is R9 and why does it matter?

The separate index for saturated red. It is not part of Ra and can be low on LEDs despite a good Ra; then skin, meat, wood and red fabric look dull.

What CRI do I need at home?

We recommend Ra ≥ 90 and R9 at least 50 for living spaces and the kitchen; for a pantry or garage the EU minimum Ra ≥ 80 is enough.

What CRI does an office need?

EN 12464-1:2021 sets Ra ≥ 80 for office work (writing, reading, typing) and Ra ≥ 90 for colour inspection and examination rooms.

Is TM-30 better than CRI?

It is more precise: 99 samples, and gamut (Rg) as well as fidelity (Rf). But regulations and standards still use Ra, so we look at both.

Is R9 mandatory in the EU?

There is no minimum, but the R9 value must be declared on the EPREL product sheet of LED light sources.

Let’s talk about your project.

Tell us what you are planning and we will get back to you within a few days.

Get in touch

Cookie settings

Choose what you consent to. We remember your choice for 6 months; change it any time via “Cookie settings” in the footer.

Privacy notice