Connecting a light fitting: what you can do yourself and when you need an electrician
Connecting a light comes down to three wires: the live (L) goes to the luminaire through the switch, the neutral (N) and the protective earth (PE) go directly. Replacing a light with an identical one on an existing outlet is simple, provided the circuit is switched off, the absence of voltage is tested and there is an earth wire. You need an electrician if there is no earth, if a new outlet, switch or motion sensor is needed, for a heavy chandelier, and in bathrooms and outdoors.
In short
- Bulb or plug-in lamp: changing a lamp or using a plug-in floor or table lamp needs no installer.
- Identical light on an existing outlet: can be done if the circuit is off, the absence of voltage is tested with a two-pole tester and the wires are unambiguous.
- Call an electrician if there is no earth or the wiring is aluminium, if a new outlet, switch, dimmer or motion sensor is needed, for a heavy chandelier, and in bathrooms and outdoors.
- Safety: lighting circuits in a home must be protected by a 30 mA RCD (HD 60364-4-41:2017).
Author: Norbert Madarász
, Managing Director and Partner · Updated: 14 November 2026
Which wire goes where?
A ceiling or wall outlet usually has three wires. The switch breaks the live conductor, so with correct wiring the light is safe to change when switched off. In older houses you cannot rely on the colours: the marking may differ, and sometimes the switch breaks the neutral.
| Wire | Colour (current marking) | Where it goes |
|---|---|---|
| Live (L, switched: L') | brown, black or grey | to the L terminal of the luminaire, via the switch |
| Neutral (N) | blue | to the N terminal |
| Protective earth (PE) | green-yellow | on a metal (class I) luminaire to the ⏚ terminal; on a double-insulated (class II) luminaire it stays insulated in a connector |
Today the wires are joined with spring or lever connectors (a luminaire terminal block); twisting and tape are not a solution. On a metal luminaire the earth is connected first and disconnected last.
What can you do yourself, and what is the electrician’s job?
Three things matter: the finished installation must meet safety requirements and the standard (HD 60364), whoever does the work is liable for faults, and luminaire installation instructions typically require a qualified installer. In practice:
| Job | DIY? | Why |
|---|---|---|
| Changing a bulb, plug-in lamp | yes | no contact with the wiring |
| Identical light on an existing outlet, with earth | carefully, yes | if the circuit is off and tested and the wires are unambiguous |
| Old house, no earth, aluminium wiring | no | needs an assessment; the fix is not just the luminaire |
| New outlet, new switch, two-way or intermediate switching | no | chasing, new cable, wiring diagram |
| Motion sensor, dimmer, smart switch | better not | neutral, minimum load, compatibility |
| Heavy chandelier, plasterboard ceiling | no | the fixing’s load capacity matters as much as the wiring |
| Bathroom, outdoors | no | zones, IP rating, RCD |
Why an electrician should connect the light (protection against electric shock, old wiring, fixing) is covered on our LED lighting page: Why should an electrician connect a light fitting?
Changing a light safely, step by step
- Switch off at the circuit breaker, not just at the wall switch. If it is unclear which circuit it is, use the main switch.
- Test for absence of voltage with a two-pole voltage tester between all conductors (L–N, L–PE, N–PE). A test screwdriver is not reliable for this.
- Remove the old light and mark the wires; if the colours are unclear, stop here.
- Fixing: the bracket into the ceiling, the chandelier on the hook; in plasterboard only with an anchor rated for the load or into the substructure.
- Connect: earth, neutral, live, in a connector; no bare ends, no kinked wires under the canopy.
- Test: switch back on; if the breaker trips or the light is on regardless of the switch, switch off immediately.
Connecting a motion sensor light
A light with a built-in sensor is connected like any other: L, N, PE. The wall switch then switches the sensor off; with the switch off, the sensor does not work either. So the switch in front of such a light is usually left on or replaced by a blank plate.
With a separate motion sensor the key question is whether it gets a neutral:
| Sensor | Wiring | What to watch |
|---|---|---|
| 3-wire (with neutral) | L and N in, L' out to the light | powered via the neutral, works well with small LED loads (from 0 W in Legrand’s Mosaic catalogue) |
| 2-wire (no neutral) | in place of the switch, L in, L' out | powers itself through the lamp, so it needs a minimum load (3 W LED in the Legrand example); with few LEDs it may flicker or flash |
- Position: a passive infrared (PIR) sensor detects best across the direction of movement; at the end of a corridor, on the stair landing.
- Settings: light threshold (dusk sensing), run-on time, sensitivity.
- Several sensors on one light: only as the manufacturer specifies, in parallel or as master and slave.
- Outdoors at least IP44 for sensor and light, with the circuit on an RCD.
Where people sit, use a presence detector instead of a motion sensor, because it also picks up small movements. More on stairs and corridors on our LED page: LED lighting and lighting control.
Connecting a chandelier: switching and fixing
- Two switched lives: to switch groups of lamps separately, the outlet needs two switched lives (L1', L2') and a double switch. If there is only one, adding it means chasing the wall.
- Fixing: the ceiling hook or mounting plate must go into the structure; a plasterboard sheet alone does not carry the weight of a chandelier.
- Dimming: only with dimmable lamps and a matching dimmer, otherwise it flickers (LED dimmer switches).
- Height: above a dining table the bottom of the pendant about 55–70 cm above the top; see kitchen and living room lighting.
IKEA, EGLO, Rábalux, SLV, Kanlux: installing a light bought elsewhere
You do not have to buy the light from us: we also install lights bought online or in a store. Whatever the brand, we check the same things before unboxing:
| What we check | Why it matters |
|---|---|
| Protection class (I or II) | a class I metal light needs a protective earth at the outlet |
| IP rating | in the bathroom the zone, outdoors the weather sets the minimum |
| Weight and fixing | on a plasterboard ceiling the structure or a load-rated anchor decides |
| Integrated LED or socket | with integrated LED the light source cannot be replaced; the driver is inside the fitting |
| Remote, app, smart function | the light needs permanent power, so the wall switch stays on |
What matters for installation, brand by brand:
- IKEA: some wall lights are plug-in and need no wiring (for the VARMBLIXT wall lamp IKEA itself says no electrician is needed). Ceiling and fixed wall lights are connected to the outlet. The smart products (TRÅDFRI, DIRIGERA) run through the DIRIGERA hub, which is also a Matter bridge.
- EGLO: many ceiling lights come with a remote or as connect.z smart versions (Zigbee 3.0 and Bluetooth, controlled by app, wall switch or remote). Remote and app only work while the light has power, so the wall switch is often replaced by a blank plate or a smart push button.
- Rábalux (based in Győr, Hungary) and Kanlux: a wide indoor and outdoor range. For outdoor and bathroom use we check the IP rating on the label; for outdoor motion-sensor lights we also set up the sensor.
- SLV: professional spot and track systems. Single-circuit track is simpler; on three-circuit track the lights can be split across three circuits and switched in groups (SLV guide). The track feed and the outlet position are best decided at the design stage.
We install single lights too, but it is best when one visit covers several lights in the home.
What does installing a light cost?
It depends on how many lights, whether there is an outlet and an earth wire, the type of ceiling, and whether a new switch, sensor or dimmer is needed. So we do not publish a price list: we quote after a site visit. We also install single lights, but the best value is to do several lights, switches or sockets in one visit.
If the condition of the wiring is in doubt, an electrical safety inspection gives a clear picture. In bathrooms the zones matter: bathroom lighting; in the garden and on the facade: garden and outdoor lighting.
Related articles from our knowledge base
Buried cable and conduit, IP ratings, RCDs, dusk sensors, motion sensors, extra-low voltage – and facade lighting.
Read →What the standard allows in zones 0, 1 and 2, which IP rating you need, where switches go, and good light at the mirror.
Read →WAGO 221 and 2273, screw and spring terminal blocks: which wire, what current, and where joints are allowed.
Read →Frequently asked questions
Can I connect a light myself?
Replacing an identical light on an existing outlet can be done if the circuit is off, the absence of voltage is tested and there is an earth wire. The work must meet safety requirements, and whoever does it is liable. New outlets, switches, sensors, bathrooms and outdoor work are for an electrician.
Which wire is live, neutral and earth?
With current marking, live is brown, black or grey, neutral is blue, earth is green-yellow. In older houses the colours cannot be relied on; test them.
What if there is no earth wire at the outlet?
A metal class I luminaire cannot be connected safely. A double-insulated class II light may be an option, but the old wiring should be assessed.
How is a motion sensor light wired?
A light with a built-in sensor like a normal light (L, N, PE), with the wall switch left on. For a separate sensor, the 3-wire type with neutral is the reliable choice with LEDs; a 2-wire sensor needs a minimum load.
Why does the LED flicker after a motion sensor or dimmer?
Usually because a sensor or dimmer without neutral powers itself through the lamp and the LED load is too small. The fix is a sensor with neutral or a dimmer matched to the lamp.
What does it cost to install a light?
It depends on the number of lights, the outlet, the ceiling and the switching, so there is no price list; we quote after a site visit.
Do you install lights bought elsewhere (IKEA, EGLO, Rábalux)?
Yes, whatever the brand. Beforehand we check the protection class, the IP rating, the weight and the fixing; with remote-controlled or smart lights the wall switch stays on or is replaced by a blank plate.
Why does the remote-controlled light stop working when I switch it off at the wall?
Because the remote receiver and the smart module are powered by the light. With the wall switch off the light cannot receive a signal. The switch stays on, or is replaced by a blank plate or a smart push button.
Let’s talk about your project.
Tell us what you are planning and we will get back to you within a few days.
Get in touch