48 V magnetic track lighting: what to decide before the plasterboard goes up
A magnetic track system is an extra-low-voltage (24 or 48 V DC) track: the light heads attach by magnet and can be moved along the track without tools. The track is fed from a SELV power supply (safety extra-low voltage), not directly from the mains like a 230 V track. In a suspended ceiling the recessed version looks best, but it has to be installed before the plasterboard goes up – and by then the track route, the power supply location and the control (DALI, KNX, Casambi) must be decided.
In short
- What is it? An aluminium track with extra-low-voltage conductors; the light head clips on with a magnetic adapter, no tools needed (e.g. ISOLED Track48).
- 230 V or 24/48 V? A 230 V (single or three-circuit) track runs on mains voltage; a magnetic track runs from a power supply at SELV, as a protection class III system (SLV, Philips Hue).
- 24 or 48 V? For the same power, 48 V needs half the current, so losses are lower and a longer track or more lights fit on one feed. The exact limit always comes from the manufacturer.
- Drywall: the recessed profile goes in before boarding; its installation depth depends on the product (45 mm for the Flos profile).
- Control: there are on-board dimming, DALI, 1–10 V, Casambi and Zigbee versions; from KNX we control it through a DALI gateway.
- Brands: track, power supply and light heads form one system. SLV explicitly forbids mixing its parts with those of other track systems.
Author: Norbert Madarász
, Managing Director and Partner · Updated: 15 November 2026
What is the difference between a 230 V track and a 24/48 V magnetic track?
Classic track lighting runs on 230 V: on a single-circuit track all lights share one circuit, on a three-circuit track they can be split into three groups and switched separately (more in connecting a light fitting). Paulmann URail, for example, is described by the manufacturer as a 230 V system. A magnetic track is extra-low voltage: the power supply connects to the mains, and the track carries only 24 or 48 V DC.
| Aspect | 230 V track (single or three-circuit) | 24/48 V magnetic track |
|---|---|---|
| Voltage on the track | mains, 230 V | 24 V (e.g. Philips Hue Perifo, Rábalux LiTrack) or 48 V DC (e.g. SLV 48V TRACK, Flos The Tracking Magnet) |
| Supply | directly from the mains | from a separate power supply; per SLV, only a SELV supply for class III equipment may be connected to the feed |
| Fixing the light head | with the adapter of the track system | with a magnetic adapter, no tools (ISOLED Track48) |
| Size | varies by manufacturer | slim profile; the Flos system is 15 mm wide |
| Typical use | shops, galleries, homes | homes, offices, shops; recessed into the ceiling as a barely visible line |
For homes, the magnetic track is now the usual choice: it is slim, can sit flush with the ceiling, and spots, linear lights and pendants can be combined on one track. A 230 V track makes sense when existing fittings are made for it, or when high-output spots must run along a long track.
24 V or 48 V: which one, and how long can a track run be?
The difference is physics: power is voltage times current (P = U × I). A 30 W group of lights needs 1.25 A at 24 V and 0.625 A at 48 V. The voltage drop along the conductors is proportional to the current (U = I × R), and the heat loss to the square of the current. So at 48 V the same track can feed a longer run or more lights from one point before the lights towards the end visibly dim.
The exact limit always comes from the manufacturer and differs between systems. On the SLV 48V TRACK, for example, at most 16 A may flow; the power supply rating is a further limit. There is no general run length valid for every system: if a shop or a summary gives one number, check it against the actual product.
- Total power of the lights: the wattage of all light heads, including those you plan to add later.
- Feed position: at the end of the track or, where the system offers it, in the middle; a centre feed splits the load into two shorter branches.
- Power supply and track rating: the lower one counts. If the load is higher, the track is split into sections, each with its own feed.
- 24 V systems (e.g. Philips Hue Perifo, Rábalux LiTrack) suit smaller rooms and shorter tracks; in a larger living room, office or shop, 48 V systems give more headroom.
Recessed, surface-mounted or suspended: what does it mean for drywall?
Most magnetic track systems come in three versions: recessed (flush with the ceiling or wall), surface-mounted (on the finished ceiling) and suspended (on wires). ISOLED Track48 also has a dedicated drywall rail.
- Recessed (plaster-in) profile: the track runs flush with the plasterboard, only a narrow slot is visible. Flos recommends it where the profile can be installed before the suspended plasterboard ceiling; its installation depth is 45 mm. That much space is needed above the board, including the cables.
- Fixing in a suspended ceiling: according to the SLV manual, in a cavity ceiling the track must be fixed to a solid background with the system suspensions, and ceiling elements placed against the track must not load it.
- Surface-mounted track: can be added to a finished ceiling later without opening it; only a cable outlet at the feed point is needed.
- Suspended track: for high ceilings or above the dining table; the feed cable comes down along the suspension.
For a recessed track, decide before boarding: the route and length, the corners (Flos: no spots in the corner piece), the feed point, the power supply location and, if used, the DALI cable. It is the same checklist as for hidden LED strips: hidden LED strip lighting in drywall.
Where does the track power supply go, and what size?
The power supply of a magnetic track runs from the 230 V mains and outputs safety extra-low voltage (SELV). According to SLV, only a SELV supply intended for protection class III equipment may be connected to the track feed. Connecting the mains side of the supply is an electrician job.
- Sizing: add up the wattage of the light heads; Philips Hue says the same for its 100 W Perifo supply. The supply is chosen with headroom (see what size of LED driver).
- Location: accessible and ventilated, behind an access panel, not sealed behind the plasterboard; a power supply can fail and must be replaceable.
- Several sections: if the total load exceeds the rating of the supply or the track, you need several supplies and several feeds.
- Manufacturer supply: most manufacturers offer their own supplies for their track; Flos, for example, lists a 48 V, 320 W supply for its system.
How is it dimmed and controlled: DALI, KNX, Casambi, Zigbee?
The control options depend on the track and the light heads, so the system is chosen together with the control. Flos The Tracking Magnet, for example, has one profile for lights with on-board dimming and another for DALI, 1–10 V and Casambi-controlled lights.
| Control | How it works | Best for |
|---|---|---|
| On-board dimmer, app (e.g. Casambi) | each light head has its own driver, controlled over a Bluetooth mesh | later extensions where there is no bus cable |
| Zigbee, Bluetooth (e.g. Philips Hue Perifo) | the lights join the smart home radio network | homes already using Hue |
| DALI or 1–10 V | the DALI control cable runs to the profile or the power supply | new builds and renovations where the other lights are DALI too |
| KNX | via a KNX–DALI gateway the DALI track becomes part of the KNX system | KNX homes: scenes, motion sensors, central switching |
A wall phase-cut dimmer only works if the power supply datasheet explicitly allows it (LED dimmer switch). We design and program KNX systems and wire DALI ourselves: DALI lighting control, choosing DALI drivers and controllers, KNX smart home.
Which lights fit on the track, and can brands be mixed?
- Spot: adjustable accent light for pictures, shelves, worktops.
- Linear light: even general lighting along the track.
- Pendant: above the dining table or kitchen island (kitchen and living room lighting).
- Light quality: check colour rendering and colour temperature on the datasheet as for any light (CRI, R9, tunable white).
Brands are not interchangeable. The SLV manual states that the components and luminaires of the system may not be combined with protection class I or II track systems or with any other track system, and that the user is responsible for the electrical and thermal compatibility of the track and the lights connected to it. In practice we therefore choose the track, the supply and the light heads from one series of one manufacturer, and check that it will still be available in years to come.
Popular magnetic track systems: SLV, Flos, Philips Hue, Rábalux, ISOLED
According to Google search data (November 2026), these brands are among the best known in track lighting in Hungary and in German-speaking countries. The table shows the manufacturers' own data; it is not a recommendation or a partnership: we install whichever system the client chooses, based on the datasheet.
| System | Voltage | Manufacturer data |
|---|---|---|
| SLV 48V TRACK | 48 V DC | recessed version for cavity and solid ceilings; max. 16 A on the track; protection class III |
| Flos The Tracking Magnet | 48 V | recessed (45 mm deep), surface and suspended; DALI, 1–10 V, Casambi; IP20 |
| Philips Hue Perifo | 24 V | protection class III; Zigbee and Bluetooth; power supply up to 100 W |
| Rábalux LiTrack | 24 V | slim magnetic track system |
| ISOLED Track48 | extra-low voltage (48 V) | recessed, surface-mounted, drywall rail, pendants; magnetic adapter, no tools |
| Paulmann URail | 230 V | not extra-low voltage; listed for comparison |
Online shops also sell many other, cheaper 48 V magnetic tracks. For those we check the same things: power supply and track rating, installation depth, control options, and whether the series will remain available.
What drives the cost of a magnetic track system?
- Track length and version: a recessed track needs work coordinated with the drywall installer; surface or suspended tracks are simpler.
- Number and type of light heads: spots, linear lights, pendants; the manufacturer and the series.
- Number of power supplies and feeds: depends on the load and the track length.
- Control: on-board dimming and app, DALI, or integrated into KNX.
- Design: lighting plan, track route, power supply location, access panels.
Who should design and install it?
According to the SLV installation manual, installing the system requires expert knowledge and may only be carried out by an approved electrician in line with local regulations. Connecting the 230 V side of the power supply, the feed and the DALI or KNX control is electrician work; the owner can then put the light heads on the track.
We cover the whole chain: lighting design, agreeing the track and power supply positions with the drywall installer, installation, and DALI and KNX programming. If you are still before the plasterboard stage, now is the time to get in touch.
Related: LED lighting and lighting control · hidden LED strip lighting in drywall · connecting a light fitting
Frequently asked questions
Is a 48 V track safer than a 230 V track?
The track carries safety extra-low voltage: under HD 60364-4-41 the limit is 120 V ripple-free DC, and manufacturers rate such tracks as protection class III. The mains side of the power supply is still 230 V, and connecting it is electrician work.
Can the lights be moved along the track?
Yes, the light head clips on with a magnetic adapter, without tools, and can be moved. Whether this is allowed while the system is live is stated in the manufacturer manual; SLV requires disconnection from the mains before cleaning.
Can a magnetic track be added to an existing suspended ceiling?
Surface-mounted and suspended tracks can, without opening the ceiling. Manufacturers (e.g. Flos) recommend installing the recessed profile before the plasterboard ceiling is finished; later only by opening the boards.
Can magnetic track lights be dimmed?
Yes, depending on the system: on-board dimming with an app, DALI, 1–10 V, Casambi or Zigbee. With a wall phase-cut dimmer only if the power supply datasheet allows it.
Can a magnetic track be controlled from KNX or DALI?
Yes, if you choose a DALI power supply or a DALI profile. From KNX we control it through a KNX–DALI gateway, so the track becomes part of scenes, motion sensor and central switching.
Are tracks and lights from different brands compatible?
No. The SLV manual states that the components of the system may not be combined with parts of other track systems. We choose track, supply and light heads from one series of one manufacturer.
How many lights can one power supply feed?
Add up the wattage of the light heads and stay below the rated power of the supply, with headroom. The track has its own limit too (16 A on the SLV 48V TRACK); if the load is higher, you need several supplies and feeds.
Do I need an electrician to connect track lighting?
Yes, for connecting the 230 V side of the power supply; according to SLV, the system may only be installed by an electrician. The owner can then put the light heads on the track.
Let’s talk about your project.
Tell us what you are planning and we will get back to you within a few days.
Get in touch